All pipe sizes are manufactured in ten foot lenghts with a 6 mil polyethylene protective sleeve, belled ends, and solvent joints. Fittings available in corresponding diameters.
| Insulated PVC comes readily available in: |
| Inside Diameter |
Outside Diameter |
Schedule of PVC Pipe |
R-value of Foam |
| ¾" |
6" |
SCH 40 |
19 |
| 1" |
6" |
SCH 40 |
17 |
| 1½ |
6" |
SCH 40 |
15 |
| 2" |
6" |
SCH 40 |
13 |
| 2" |
8" |
SCH 40 |
21 |
| 2" w/ PVC Jacket |
4" |
SCH 40 |
6 |
| 2" w/ PVC Jacket |
6" |
SCH 40 |
13 |
| 3" |
8" |
SCH 40 |
17 |
| 4" |
8" |
SCH 40 |
13 |
| 4" |
8" |
SDR 35 |
15 |
| 4" |
10" |
SDR 35 |
22 |
| 4" |
10" |
SCH 40 |
20 |
| 4" |
6" |
2729 |
6 |
| 4" w/ PVC Jacket |
8" |
SCH 40 |
13 |
| 4" w/ PVC Jacket |
8" |
SDR 35 |
14 |
| 6" |
10" |
SDR 35 |
14 |
| 6" w/ PVC Jacket |
10" |
SDR 35 |
14 |
| 6" |
10" |
SCH 40 |
13 |
| 6" w/ PVC Jacket |
10" |
SCH 40 |
13 |
| 8" w/ PVC Jacket |
12" |
SDR 35 |
13 |
| 10" w/ PVC Jacket |
15" |
SDR 35 |
17 |
| 12" w/ PVC Jacket |
18" |
SDR 35 |
20 |
In sub-zero weather, all it takes is a dripping faucet or a toilet not shutting completely off to make your sewer line freeze solid. By installing insulated PVC pipe you are able to "frost-proof" your water / sewer lines at an affordable price, with a product that is user friendly.
| Load Testing Results: All loads in pounds |
| Specimen |
Deformation First Visible to Naked Eye |
Pipe Cross Section Crushed Shut |
| ¾ Schedule 40 |
4500 |
13970 |
| 1" Schedule 40 |
|
16800 |
| 1½ Schedule 40 |
|
11230 |
| 2" Schedule 40 |
4970 |
16100 |
| 2" Schedule 40 4" Schedule 40 Jacket |
6760 |
26940 |
| 2" Schedule 40 6" PVC outside jacket |
3420 |
26870 |
| 2" Zone D |
3380 |
15980 |
| 3" Schedule 40 |
5290 |
26930 |
| 4" SDR 35 |
1330 |
4570 |
| 4" SDR 35 Zone D |
2080 |
4530 |
| 4" SDR 35-4 8" PVC outside jacket |
1700 |
15060 |
| 4" Schedule 40 |
4560 |
23850 |
| 4" Schedule 40 8" PVC outside jacket |
6120 |
13080 |
| 4" 2729 1" foam |
730 |
1750 |
| 6" SDR 35 |
1390 |
5310 |
| 6" SDR 35 10" PVC outside jacket |
1700 |
7600 |
| 6" Schedule 40 |
2500 |
11910 |
| 8" SDR 35 12" PVC outside jacket |
2900 |
12100 |
| 10" SDR 35 15" PVC outside jacket |
1700 |
10200 |
| Insulated PVC can significantly extend the time to freeze. |
| Inside Diameter |
Schedule of PVC Pipe |
R-value of Foam |
Hours to Freeze |
| ¾" |
40 |
0 |
2.25 hrs |
| ¾" |
40 |
19 |
23 hrs |
| 1½ |
40 |
0 |
3 hrs |
| 1" |
40 |
17 |
37 hrs |
| 1½" |
40 |
0 |
4.5 hrs |
| 1½" |
40 |
15 |
60 hrs |
| 2" |
40" |
0 |
5 hrs |
| 2" |
40 |
13 |
68 hrs |
| 2" |
40 (Zone D) |
21 |
93 hrs |
| 3" |
40 |
0 |
13 hrs |
| 3" |
40 |
17 |
121 hrs |
| 4" |
SDR 35 |
0 |
17 hrs |
| 4" |
SDR 35 |
6 |
94 hrs |
| 4" |
SDR 35 |
15 |
158 hrs |
| 4" |
SDR 35 (Zone D) |
22 |
222 hrs |
| 6" |
SDR 35 |
0 |
27 hrs |
| 6" |
SDR 35" |
14 |
286 hrs |
* All data compiled by Dickson Model Ktx Remote Temperature Recorder.
* Initial water temperature at 75F. Test conducted at -13° F ambient temp ± 3°
We at INSUL-SEAL ® INSULATED PVC INCORPORATED, are prepared to work with you to fit our product-line to your unique application. We are proud of our products, our company and out employees. For further information and possible "CUSTOM" applications, please
contact us